8 Main menu value call-up
Current volumetric flow Current volumetric air
Supply air fan speed
Exhaust air fan speed
Time remaining until ex-
ternal filter change
Time remaining until
unit filter change
Time remaining until
room filter change

8.3 Temperatures

Parameters
T room reference
T outside air upstream
of EHE
T air inlet, unit
T supply air
T exhaust air
T outgoing air

8.4 Sensors

Parameters
Value of sensor 1
flow
Current fan speed
Current fan speed
Remaining time (days),
until external filter has
to be changed
Remaining time (days),
until unit filter has to be
changed
Remaining time (days),
until room filter has to
be changed
Display
Temperature of the
temperature sensor se-
lected under Room
sensor configuration. A
set room temperature
adjustment is taken into
account.
Room temperature
measured at an ex-
ternal room sensor. A
set room temperature
adjustment is taken into
account.
Measured outside air
temperature down-
stream of brine earth
heat exchanger and/or
at unit input.
Supply air temperature
measured in the unit.
Exhaust air temperature
measured in the unit
(combi sensor).
Outgoing air temperat-
ure measured in the
unit.
Display
Saved sensor type, its
room assignment or the
current measurement or
selected function and
its status.
Value of sensor 2
Value of sensor 3
Value of sensor 4
Sensor for relative hu-
midity r. h. external
(KNX or Modbus)
Sensor for air quality
AQ, external
(KNX or Modbus)

8.5 Switching statuses (outputs)

Parameters
Supply air fan
Exhaust air fan
Bypass shutter
Heat register
Switching contact Basic
circuit board (main
board)
Brine circulation pump
(ZP 1)
Zone shutter (ZP1)
3-way air shutter
Supplementary heating
relay (ZP1)
Saved sensor type, its
room assignment or the
current measurement or
selected function and
its status.
Saved sensor type, its
room assignment or the
current measurement or
selected function and
its status.
Saved sensor type, its
room assignment or the
current measurement or
selected function and
its status.
Saved sensor type, its
room assignment and
the current measured
value. These sensors
are also taken into ac-
count in Auto Sensor
mode.
Saved sensor type, its
room assignment and
the current measured
value. These sensors
are also taken into ac-
count in Auto Sensor
mode.
Display
Supply air fan on or off
Exhaust air fan on or off
Bypass position open or
closed
Heat register on or off
Switching contact relay
active or inactive
Brine circulation pump
on or off
Zone shutter open or
closed
3-way air shutter, EHE
open or closed
Supplementary heat re-
gister active or inactive
35