CCT
Framing system
Control protocols
Data connections
DMX modes
DMX functions
RDM functions
Stand-Alone
System settings
User interface
Display / Indicators
IP-rating
Ambient temparature
rating
Humidity rating
Cooling system
Noise level
Operation voltage
Max. current
Max. power consump-
tion
Standby power
Fuse
Power connection
Power link
Minimum distance to
illuminated surface
34
1800K - 8000K
Manual framing blades
DMX, RDM, Unicon Remote; Optional W-DMX with IDMX Stick;
EZ-Remote
XLR 5-pin In/Out; I-DMX Slot
1CH DIM; 2CH Dim 16bit; 2CH CCT; 3CH RGB; 4CH CCT; 5CH RGBAL;
6CH HSI CCT; 7CH RGB CCT; 10CH RGBAL 16bit; 10CH HSI CCT; 11CH
Direct CCT; 18CH Full
Dimmer; Dimmer fine; Strobe Functions; Red; Red fine; Green; Green
fine; Blue; Blue fine; Amber, Amber fine; Lime; Lime fine; Hue; Satura-
tion; Color Temperature; Tint; Color Presets; Color Preset Crossfade;
Device Settings
Cameo RDM Standard
Encoder modes: CCT, HSI, Direct LED, GEL, User Color, Play Loop; Slave
DMX Address; DMX-Mode; Stand-Alone; Slave; EZ-Remote; Edit User
Color; Edit Loop; Wireless Settings; Display Flip; Display Off Timer; Sig-
nal Fail; Dimmer Curve; Dimmer Response; Redshift; PWM Frequency;
Color Calibration; Auto Lock; Fan; Factory Reset; UC/Loops Reset;
System Info
3 x Push-and-turn-encoder
OLED display
IP 20 indoor use
-10° – 45°C
<80% non condensing
Forced convection with silent Fan; Fan off operation
35.5 dB @ auto fan full on
100 V AC – 240 V AC / 50 Hz – 60 Hz
1.47 A @ 230 V; 2.89 A @ 110 V
327 W @ 230 V; 330 W @ 110 V
42 W
T 6.3 AL 250 V
True 1 compatible In / Out
5 units @ 230 V; 3 units @ 110 V
0.5 m