7

Electrical Connection

Electrical connection diagram for the output line
of the BAE sensor amplifier.
BAE00KJ, BAE00LA
• Voltage output: Load resistance min. 1 kΩ
and max. 10 kΩ between analog and minus
• Current output: Load resistance min. 0 Ω
and max. 400 Ω
BAE00LC
M12
Connection cable + plug-in unit (BAE output)
1
brown (+)
4
black (Analog out)
3
blue (–)
2
Not relevant for teach-in (generally connected to
minus)
www.balluff.com
8
The following extension cables are available for
extending the connection between the sensor
head and the BAE sensor amplifier:
Order code
BCC0E4J
Analog
BCC04JY
BCC04JZ
norm. Operation
NOTE
The maximum permissible length of the
connection cable between the sensor head and
BAE sensor amplifier is 10 m.
Route the remainder of the cable in
serpentine shape and not ring shape.
9
Sensor adjustment is carried out by BAE sensor
amplifier.
NOTE
The level application can be calibrated only after
the curing time of the adhesive has elapsed and
installation is finished. Later mechanical changes
including cable routing may affect the
measurement value.
Calibrate sensor:
1. Press
interruption.
>
>
2. Use keys to select
Display
8
(
)conf
3. Confirm by pressing
4. Use keys to select

Cable routing

Length
0.5 m
3 m
8 m

Calibration

for at least 8 s without
>
The remaining time is shown in the
display (in seconds).
>
The first menu item (i n ) is displayed
(analog value in digits).
or
Configuration
Submenu: Configuration
or
english
.
key.
.
7