Herunterladen Inhalt Inhalt Diese Seite drucken

Malfunctions; Troubleshooting Guide - Truma Mover XT Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für Mover XT:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mover XT XT2
engaged, the system issues a warning while the re-
mote control is still switched on�
5.8.3 Battery cut-off switch
Depending on the installation in the caravan, also
disconnect the power supply for the manoeuvring
system using the battery cut-off switch�
Fig. 35
Turn the key in an anti-clockwise direction� This inter-
rupts the power supply to the manoeuvring system�
Remove the key of the battery cut-off switch and
keep it in a safe place that is inaccessible to children�
60020-00204 ∙ 00 ∙ 08/2022
6

Malfunctions

6.1

Troubleshooting guide

Before contacting Customer Service:
Check whether the batteries in the remote control
are working perfectly�
Is the remote control paired with the control unit?
Pairing the electronic control unit with the radio remote
control see Kapitel 6�2�
Check that the caravan's 13-pole plug or adapter is
properly plugged into the safety socket�
Check that the caravan battery is in good condition
and is fully charged�

Battery performance can deteriorate considerably at
cold ambient temperatures�
Check that the fuse in the battery connector cable is
in order� If the fuse is defective, check the system for
possible short circuits�

If errors occur, the remote control always switches
off once the symbols have been shown�
Malfunction
Cause and remedy
Manoeuvring
system not
working
Control unit is overheated�
Manoeuvring
system not wor-
king and red LED
on control unit
flashing
Malfunctions
Check the power supply (the
green LED on the control
unit must be lit)� Replace a
defective fuse in the battery
connection cable of the ma-
noeuvring system only with
an original Truma spare part
(part no� 60040-00169)�
Interrupt the power supply
for at least 20 seconds� Res-
tore the power supply� The
green LED on the control unit
should be lit�
Interrupt the power supply
with the battery cut-off switch
and remove the key� Allow the
control unit to cool down for
at least 20 minutes� Then start
the manoeuvring system�