Product description
4.1.2 Setup of the drive unit
1
2
Fig. 3
1
Drive roller
2
Electric motor
3
status display Engaging and disengaging
4
Emergency disengaging mechanism
4.1.3 Setup of the power supply
WARNING
Fire hazard due to the control unit being co-
vered inside the caravan
If the control unit is inadequately ventilated, it
may overheat during operation�
Adequately ventilate the control unit�
Do not cover the control unit�

Drawing serves as an example (Mover XT control
unit)
1
2
3
Fig. 4
1
Battery
2
Negative terminal
3
Positive terminal
4
Fuse
5
Isolating switch
6
Remote control
30
EN
3
4
4
5
6
4.2

Product label

The appliance type and serial number are printed on the
type plate�
Type plate
To ensure that the general operating permit (ABE) is va-
lid, the type plates must be present on the left and right
of each of the mounting tubes�
Fig. 5
The type plate of the remote control can be found in the
remote control's battery compartment�
The type plate of the control unit is located on the un-
derside of the control unit�
4.3

Function

Coping with inclines (max. climbing ability)
The Mover XT has been designed to cope with inclines
of up to 25 % bearing a gross weight of 1200 kg or
13 % bearing a gross weight of 2300 kg on a suitable
surface�
The Mover XT2 has been designed to cope with incli-
nes of up to 25 % bearing a gross weight of 1200 kg or
10 % bearing a gross weight of 2400 kg on a suitable
surface�

13 % = 13 metre difference in altitude over a dis-
tance of 100 metres
Once the drive rollers have been engaged against the
tyres using the remote control, the manoeuvring system
is ready for operation�
Manoeuvring is carried out exclusively via the remote
control, which transmits radio signals to the control
unit� A separately installed 12 V lead-acid battery or sui-
table lead-gel battery (not supplied) provides the control
unit with electrical power�
4.4

Power supply

Always observe the operating instructions and the
"Safety instructions" prior to starting� The vehic-
le user is responsible for correct operation of the
device�
4.4.1 Power supply
For optimum operation, we recommend the Truma Po-
werSet BC and high-performance Optima® batteries�
Mover XT XT2
2
1