Measuring tolerances
Accuracy in ± (% of reading + display error in counts (= number of smallest
points)). These accuracy readings are valid for one year at a temperature of +23 °C
(± 5 °C) and a relative humidity of less than 75 % (non-condensing). If the mul-
timeter is used outside of this temperature range, use the following coefficient to
calculate the accuracy. +0.1 x (specified accuracy)/1 °C
The accuracy of measurements may be affected when the multimeter is used in a
high-frequency electromagnetic field.
Direct voltage (V/DC)
1
Range
40.0 mV
400.0 mV
4.000 V
40.00 V
400.0 V
600 V
Only available in "mV" mode
Specified measuring range: 5–100 % of the measuring range
600 V overload protection; Impedance: 10 MΩ (mV: ≤100 MΩ)
The multimeter may display ≤5 counts if a measuring input is short-circuited.
Direct voltage (V/DC) LoZ
2
Range
4.000 V
40.00 V
400.0 V
600 V
88
Resolution
0.01 mV
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
1 V
Accuracy
±(1.2% + 8)
±(0.9% + 8)
±(0.9% + 4)
±(1.3% + 7)
Accuracy
±(1.7% + 7)