Enables or disables the BAR input TEST.
Activation of the TEST function is only possible using items SC.RF and RF/RF.SUN, consult
the specific instructions.
tst3
On: Check enabled. If the check has a negative outcome, no manoeuvre is commanded.
See Fig.15 - "BAR TEST". (AUX=4)
Off: Test disabled.
Selection of the PHOT CL input operating mode.
On: PHOT CL input enabled only in closure.
In closure: opening of the contact causes stoppage of the motor and instantaneous inver-
sion of the running direction (opens).
phcl
Off: Active PHOT CL input both in closure and opening.
In opening: opening of the contact caused by stoppage of the motor, when the photocell
is free, motor opening restarts.
In closure: opening of the contact causes stoppage of the motor, when the photocell is free,
the motor running direction inverts (opens).
Selection of the motors 1 or 2 operating mode.
1mot
On: Use for a single motor, connected to output M1
Off: Use for two motors.
Motors start order:
minv
On: motor 2 starts first in opening.
Off: motor 1 starts first in opening.
Enables or disables the "Forced opening function without mains) function (can only be
enabled with the emergency batteries connected and working).
On: Function enabled. In the event of a power cut, before the emergency battery goes
aopf
completely flat, the control panel forces an opening manoeuvre.
The automation remains open until the mains power supply is restored.
Off: Function not enabled.
Enables or disables inversion strike.
On: Function enabled. Before each opening movement, the control panel commands a 2s
ham
movement in the opposite direction to facilitate release of the solenoid valve.
Off: Function disabled.
Enables or disables the block in opening function.
blco
On: Block function enabled. Do not use on SAM gearmotors.
Off: Block function disabled.
Enables or disables the block in closure function.
blcc
On: block function enabled. Do not use on SAM gearmotors.
Off: Block function disabled.
Selects the type of electric lock used.
On: Magnetic electric lock, normally powered according to the Vloc setting. Output en-
abled with gate closed.
mloc
Off: Latch electric lock, normally not powered.
Before each opening movement, it is supplied according to the Vloc setting for the time set
by the TLOC parameter.
Enables or disables the cloned ARC transmitters.
cvar
On: The AK series transmitters closed from an ARC transmitter already stored are enabled.
Off: The cloned transmitters are not enabled.
Enables or disables remote learning of the radio transmitters, as indicated in the
"Transmitters remote learning" paragraph.
rem
On: Remote learning enabled.
Off: Remote learning disabled.
Enables or disables the "ESA" energy saving functionality.
On: The control unit, once the manoeuvre has terminated and enabling time is up of the
service light, removes the power supply to the accessories output, setting in stand-by
status.
esa
The power supply of the accessories however remains enabled, only for the necessary time,
if the AUX1/AUX2 parameters need it.
Off: Energy saving disabled. To use if you want to have the accessories power supply
always enabled, for example if using 24 Vdc, or other devices that need to be always
powered.
32
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(ON)
(ON)