2.1. Functions and ranges
Accuracy is specified for a period of one year after calibration and 18° C
... 28° C with relative humidity to 80 %.
DC Voltage
Range
400 mV
4 V
40 V
400 V
600
V
Input Impedance:
Overvoltage protection:
AC Voltage
Range
400 mV
4 V
40
V
400
V
600
V
Input Impedance:
others : 10MΩ
Frequency range: 40 ... 400 Hz
Overvoltage protection:
DC Current
Range
40 mA
400 mA
Overl. protection:
Max. input:
Resolution
0,1 mV
1
mV
10
mV
0,1
V
1
V
> 1000 MΩ at 400 mV range;
others 10MΩ
600 V DC or AC
Resolution
0,1 mV
1
mV
10
mV
0,1
V
1
V
at 400 mV range: > 1000 MΩ
600 V AC
Resolution
0,01 mA
0,1 mA
fast acting fuse 500 mA/1000 V
400 mA DC or AC
-26-
Accuracy
+/- 1,0 % + 5 dgt.
+/- 0,8 % + 3 dgt.
+/- 1,0 % + 5 dgt.
rms
Accuracy
+/- 1,5 % + 5 dgt.
+/- 1,0 % + 5 dgt.
+/- 1,2 % + 5 dgt.
or V DC
rms
Accuracy
+/- 1,2 % + 3 dgt.
rms

Werbung

loading