Herunterladen Inhalt Inhalt Diese Seite drucken

Sensor; Sensor Specifications - Grundfos MAGNA3 Montage- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für MAGNA3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 138

16. Sensor

Fig. 29 Correct position of sensor
During maintenance and replacement of the sensor, it is
important that the sealing cap is fitted correctly on the sensor
housing.
Tighten the screw holding the clamp to 5 Nm.
Warning
Before replacing the sensor, make sure that the
pump is stopped and that the system is not
pressurised.

16.1 Sensor specifications

16.1.1 Pressure
Maximum differential pressure
during operation
Accuracy
(0 to +85 °C)
Accuracy
(-10 to 0 °C and +85 to +130 °C)
* Full scale.
16.1.2 Temperature
Temperature range during operation
Accuracy
36
2 bar / 0.2 MPa
2 % *
3 % *
-10 to +130 °C
± 2 °C
Nose downwards
5 Nm