Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning And Servicing; Cleaning; Descaling - Parkside PDTA 5 A1 Originalbetriebsanleitung

Dampftapetenablöser
Vorschau ausblenden Andere Handbücher für PDTA 5 A1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
• It is best to work from the ceiling to the
floor.
• Use the small steam plate (11) to re-
move wallpaper in corners or niches
(see "Mounting and changing the large
steam plate").
• Use the large steam plate (13) to re-
move wallpaper on large areas (see
"Mounting and changing the large
steam plate").
• Place the steam plate (11/13) on the
wallpaper. Depending on the type of
wallpaper and surface, remove the
steam plate after approx. 10 seconds
and remove the wallpaper from top
to bottom or scrape off with the
scraper (9).
• Place the steam plate (11/13) on the
wallpaper repeatedly while scraping.

Cleaning and Servicing

You should have any repair and
maintenance work that is not de-
scribed in these instructions carried
out by our Service Centre. Only use
original parts.
Remove the mains plug (1) from the
socket and allow the device to cool
down before starting any work.
Perform the following cleaning and mainte-
nance work regularly. This will guarantee
long and reliable use.

Cleaning

The device must not be
sprayed with water or placed
in water. Otherwise there is
a risk of electric shock.
• Rinse the boiler occasionally with tap
water until it is clear.
Do not use any cleaning agents or
solvents. This could damage the device
irreparably.

Descaling

Never add flammable, toxic, caus-
tic or other liquids!
Descale the appliance if necessary,
depending on the water hardness
and frequency of use. Use commer-
cially available descaling agents,
preferably citric acid. Follow the
dosage and application instructions
of the descaling agent manufac-
turer!
Defects due to a lack of descaling
are excluded from the warranty.
1. Make sure that the mains plug (1) is
removed from the socket and that the
device has cooled down.
2. Pour in a commercially available des-
caling solution (2.5 litres).
3. Remove the steam hose (14) and insert
the mains plug (1).
4. Boil the descaling solution for approx.
5 minutes.
5. Remove the mains plug (1) from the
socket and allow the solution to take ef-
fect for another 10 minutes.
6. Allow the device and the rest of the so-
lution to cool down. Empty the device,
rinse it with clear water and allow it to
dry.
GB
MT
21

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis