OWNER'S MANUAL
12
• Refer to the PDB about detail electric
characteristics
• Connect the wires to the terminals on the
control board individually according to the
outdoor unit connection.
• Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as
those of indoor unit respectively
• When the connection line between the
indoor unit and outdoor unit is over 40 m,
connect the telecommunication line and
power line separately.
• Supply line of appliances shall not be lighter
than polychloroprene sheathed. (code
designation 60245 IEC 57)
Minimum cross-sectional area of conductors
Rated current of
appliance A
cross-sectional area mm
≤ 6
> 6 and ≤10
> 10 and ≤16
> 16 and ≤ 25
> 25 and ≤ 32
> 32 and ≤ 40
MAINTENANCE
Clean the product regularly to maintain
optimal performance and to prevent possible
breakdown.
!
• Turn off the power and unplug the
power cord before you perform any
maintenance;
otherwise it may cause electric shock.
• Never use water that is hotter than 40 °C
when you clean the filters. It may cause
deformation or discoloration.
• Never use volatile substances when you
clean the filters. They may damage the
surface of the product.
Nominal
Operation Tips!
2
0.75
• Do not overcool the room.
1.0
This is not good for the health and wastes
1.5
electricity.
2.5
Keep blinds or curtains closed.
•
4
Do not let direct sunshine enter the room
6
when the air conditioner is in operation.
Keep the room temperature uniform.
•
Adjust the vertical and horizontal airflow
direction to ensure a uniform temperature in
the room.
Make sure that the doors and windows are
•
shut tight.
Avoid opening doors and windows as much
as possible to keep the cool air in the room.
Clean the air filter regularly.
•
Blockages in the air filter reduce the airflow
and lower cooling and dehumidifying
effects. Clean at least once every two
weeks.
Ventilate the room occasionally.
•
Since windows are kept closed, it is a good
idea to open them and ventilate the room
now and then.
CAUTION