Herunterladen Inhalt Inhalt Diese Seite drucken

Airborne Noise Emission; Product Information - LG MU2R15 Bedienungs- Und Montageanleitung

Vorschau ausblenden Andere Handbücher für MU2R15:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 49
MODEL DESIGNATION
2
MODEL DESIGNATION

Product information

- Product Name : Air conditioner
- Model Name :
U
U
24
W
U
4
2
Serial Number
Chassis name
Indoor / Outdoor
Detailed product type
W : Inverter outdoor
WR : Inverter outdoor(R32)
WH : High COP Inverter outdoor
WC : Compact Inverter outdoor
WCR : Compact Inverter outdoor(R32)
Nominal Capacity
EX) 9 000 Btu/h Class → '09'
Type
U : Outdoor units
T : Cassette
V : Floor-ceiling
Model Type
U : Universal model
MU4 M
27
U4
2
Serial number
Outdoor unit chassis name
Nominal capacity
Ex) 18 000 Btu/h Class → '18'
Type of refrigerant
M : R410A
R : R32
Indicates that this is multi
system outdoor unit using R410A/R32
Ex) MU3 : Connectable max.
MU4 : Connectable max.
FM 40
A
H
U3
2
Serial number
Outdoor unit chassis name
Model type
H : Heat pump
Type of refrigerant
A : R410A
Nominal capacity
Ex) 48 000 Btu/h Class → '48'
Model type
FM : Inverter multi system
of Distributor Box type
- Additional Information : serial number is
refer to the barcode on the product.
- Maximum allowable pressure
High side : 4.32 MPa
Low side : 2.4 MPa
- Refrigerant : R32
The A-weighted sound pressure emitted by
this product is below 70 dB.
** The noise level can vary depending on the
site.
The figures quoted are emission level and are
not necessarily safe working levels.
Whilst there is a correlation between the
emission and exposure levels, this cannot be
used reliably to determine whether or not
further precautions are required.
Factor that influence the actual level of
exposure of the workforce include the
characteristics of the work room and the other
sources of noise, i.e. the number of
24 000 Btu/h Class → '24'
equipment and other adjacent processes and
B : Duct
the length of time for which an operator
Q : Console
P : Floor standing
exposed to the noise. Also, the permissible
exposure level can vary from country to
country.
This information, however, will enable the
user of the equipment to make a better
evaluation of the hazard and risk.
3 indoor units
4 indoor units

Airborne Noise Emission

Werbung

Inhaltsverzeichnis
loading