Head / Neck Pillow

Warnings:
- DO NOT use a product that is underinflated or overinflated, because the product
benefits will be reduced or eliminated, resulting in an increased risk to skin and
other soft tissue. Carefully follow the instructions for inflation and adjustment.
- Check inflation and adjustment frequently, at least once a day. Check inflation and
adjustment the first time and every time the individual transfers onto the product.
- During inflation, the individual MUST NOT be on the product.
Close
Open
Head / Neck Pillow Adjustment Instructions
Warning: A Hand Check MUST be performed EVERY TIME the individual transfers onto the
product. If the individual transfers off and then back onto the product, a Hand Check MUST be
performed to ensure that the product is correctly adjusted and that it will continue to provide
protection.
1. Inflate the pillow, using both inner and outer inflation valves:
a. Slide the rubber nozzle of the hand pump over the inflation valve. Pinch the nozzle of the hand
pump, and open the inflation valve.
b. Add air until all of the air cells are fully inflated.
c. Remove the hand pump. Do not close the inflation valve.
d. Allow air to escape from the inflation valve. Listen (or place your hand in front of the inflation
valve) to make sure that no more air is coming out of the pillow.
e. Close the inflation valve.
2. Use the Hand Check Method to adjust the pillow:
a. Place the individual's head / neck on the pillow.
b. Position your open hand under the individual's head / neck and feel for the lowest bony
prominence. You should barely be able to move your fingertips, and there should be 1/2 in. - 1 in.
(1.5 cm to 2.5 cm) between the lowest bony prominence and the base of the pillow.
If there is not enough air (underinflated):
If determined safe by the clinician, use the hand pump to add additional
air.
Otherwise, transfer the individual from the pillow. Use the provided hand
pump to add a small amount of air. Close the inflation valve. Repeat for
the other inflation valve. Place the individual's head / neck on the pillow.
Perform a Hand Check. There should be 1/2 in. - 1 in. (1.5 cm to 2.5 cm)
between the lowest bony prominence and the base of the pillow.
ROHO Specialized Hospital Products Operation Manual
If there is too much air (overinflated):
Keeping your hand in place, open the inflation valve, and remove a
small amount of air until you can barely move your fingertips, and
there is 1/2 in. - 1 in. (1.5 cm to 2.5 cm) between the lowest bony
prominence and the base of the pillow.
Close the inflation valve.
If needed, repeat for the other inflation valve.
4

Product Specifications

Note: All measurements are approximate.
Package contents: Hand pump, repair kit, operation manual,
limited warranty supplement and product registration card.
To order replacement parts, contact your equipment provider or
Customer Support.
Width x Length x Height
Head/Neck Pillow :
93/4 x 111/4 x 31/4 in. (25 x 28.5 x 8.5 cm)
Head / Neck Pillow
Air cells
Inner and outer
inflation valves
Hand Pump
Weight:
Head/Neck Pillow
1 lb. (0.5 kg)

Werbung