Setting of the end positions

4.4. Setting of the end positions with setting switch/switch

Note: Settings with a wired switch are only possible in automatic setting mode.
When connecting the setting switch for radio motors, consider the following:
Caution! Risk of injury through an electric shock!
Connection only when de energised!
Warning!
The 5 wires in the setting switch cable must be connected to the motor wiring cable accor-
ding to their colours.
SELVE setting switch
article no. 290109
Caution: Always connect L1 (= brown) to the permanent voltage supply 230 V even if the
motor is only connected for adjustment purposes with a switch or a setting switch.
Note: The following settings can be made with both the SELVE setting switch (article no.
290109) and the new SELVE universal setting switch (article no. 291009).

4.5. Selection table for settings

Setup-mode/end positions in operation
Automatic setup- mode
bottom position, top stop/release
Manual setup -mode
bottom position, top position
Manual setup- mode
bottom position, top stop/release
SELVE universal setting switch
article no. 291009
UP = grey
DOWN = black
N = blue
L1 = brown
PE = yellow/green
Control Up/Down
E button
Setting switch