If no manual changeover* takes place, both gas cylinders will eventually be empty at
the same time (both LEDs A + B light up red).

TROUBLESHOOTING

Fault cause
Gas smell
Leaking LPG is
extremely
flammable.
Can cause
explosions.
No LED display
Top LED display
flashes yellow
Top LED display
lights up yellow
permanently
22 / 24
A
A
Action
 Close the gas supply.
 Do not use any electric switches.
 Do not use a phone in the building.
 Ventilate rooms well.
 Shut down the LPG system.
 Contact a specialised company.
Activate remote display:
 See START-UP
 Check the cables (in particular the power supply).
Still no LED display:
 Send the Caramatic BasicControl back to the manufacturer.
Check the cables (page 8), close the gas cylinder valves, interrupt the
power supply briefly to restart the remote display, open the gas cylinder
valves:
 Top LED display no longer flashes yellow after this: everything is ok
 Top LED display flashes yellow after this, both LEDs A + B do not
light up, send the Caramatic BasicControl to the manufacturer.
The first time or repeated times that power is applied, this is indicated
by an LED test (all LEDs flash briefly).
Too high pressure between the regulators:
 Open the shut-off fittings on the connected consumer equipment. If
no pressure compensation is achieved, if the LED continues to light up
yellow:  Send the Caramatic BasicControl to the manufacturer.