3.4.3 Installation and connection of the TBi control board

The TBi control board is looped into the supply line for the drive motor of the feed unit. This requires separating
the motor supply cable. The TBi control board must be attached at a suitable place within the main feed unit. A
cable from the board to the Push-Pull plug connector must then be installed.
Danger!
Ensure that the board is installed with electrical insulation and touch-protection. The board may
only be installed by qualified personnel. The installation of the board must ensure that there is
no contact danger to system operators.
Electrical short-circuits can cause damage to the torch or power source and must be avoided.

System overview

Connection plan for TBi PP-TX without potentiometer
Only the connection for motor supply line has to be established, according to the circuit diagram. A 2-pin plug
connector is sufficient for this.