Herunterladen Inhalt Inhalt Diese Seite drucken

Using The Device; Charging The Battery - Dometic BUTTNER MT PL 1225 POWERLINE Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
2. Set the DIP switches according to the battery
type to be charged, see chapter "DIP switch
settings" on page 13.
3. Connect the positive cable from the DC output
socket + for house battery, or 5A + for starting
battery. Connect the cable to the positive ter-
minal of the battery. Protect the the positive
cable of the house battery with a 30 A fuse and
the starting battery with a 7.5 A fuse.
4. Connect the negative cable from the DC out-
put socket - of the battery charger to the nega-
tive terminal of the battery.
5. Optional, compensation for long cabling:
Connect the Sense+ and Sense- wires to the
positive and negative terminals of the house
battery. Protect the Sense+ cable with a 3 A
fuse
6. Plug the 230 V power cable into the AC INPUT
socket on the charger.
7. Plug the power cable into a 230 V socket that
is protected by a residual current circuit
breaker.
Connections for charging two house batter-
ies with MT 1250 (fig. 9, page 6)
1. Follow step 1 to 2 in the section above.
2. Connect one positive cable from each DC out-
put socket + . Connect the cables to each pos-
itive terminal of the batteries. Protect the
positive cables of the house batteries with
60 A fuses, and 7.5 A for starting battery.
3. Connect the negative cable from the DC out-
put socket - of the battery charger to the nega-
tive terminals of the batteries.
4. Optional, compensation for long cabling:
Connect the Sense+ and Sense- wires to the
positive and negative terminals of the house
battery. Protect the Sense+ cable with a 3 A
fuse
5. Follow step 6 to 7 in the section above.
14

Using the device

Charging the battery

1. Connect the battery to the DC output sockets +
and - on the charger as described in chapter
"Connect the battery to power supply" on
page 13.
– Make sure the polarity of the connection is
correct.
2. Turn the charger on with the main switch.
Switch mode
ON/REMOTE
OFF
SIGNAL
Status
The status indicator LED (fig. 2, page 3, 2) dis-
plays the operating status (see chapter "Battery
charging curve" on page 10).
The status indicator is also visible on the remote
control (accessory).
Status indicator LED
Orange, fast blinking
Orange, slowly blinking Bulk phase, charging with
Orange, constant light
Green, constant light
Green, slowly blinking
Red, constant or blink-
ing
4445103656
Description
Turn the charger on, the remote
control is active if there is one
(accessory).
Turn the charger off.
The charger will be controlled by
an external device connected to
the charger.
Description
Derating, charging with
maximum 50% current
because of low voltage
startup
constant current
Absorption phase, charging
with constant voltage
The battery is fully charged
(float phase), or DIP-switch
S4 is set to 1 (store)
Store phase, the state of
charge is maintained
Error, see chapter "Trouble-
shooting" on page 15

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Buttner mt pl 1250 powerline

Inhaltsverzeichnis