Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting Instructions; Pin Assignment - Dometic BUTTNER MT PL 1225 POWERLINE Montage- Und Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
• The place of installation must be well ventilated.
A ventilation system must be available for instal-
lation in small, enclosed space. The clearance
around the device must be at least 10 cm
(fig. 4, page 4).
• The air inlet on the front side and the fan on the
back of the charger must remain clear.
• Do not install the charger in the same area as the
batteries.
• Do not install the charger above batteries,
because they can emit corrosive sulfur fumes
that will damage the device.
• For ambient temperatures higher than 40 °C
(such as in engine or heating compartments, or
direct sunlight), the heat from the charger under
load can lead to reduced output.
• The charger must be installed on a level and suf-
ficiently sturdy surface.
• The battery charger can be installed horizontally
or vertically, as well as lying or hanging (fig. 5,
page 5).

Mounting instructions

A
NOTICE! Damage hazard
Before drilling any holes, make sure that
no electrical cables or other parts of the
vehicle can be damaged by drilling, saw-
ing and filing.
Fasten the device as follows:
1. Hold the device against the installation loca-
tion.
2. Mark the fastening points with a pen.
3. Fasten the device with one screw through
each hole in the holders.
– Use machine bolts (M4) with washers and self-
locking nuts or self-tapping screws / wood
screws.
Determine cable cross-section
Cable cross
Cable length
section
MT PL 1225
2
1.0 - 2.5 m
6 mm
12

Pin assignment

A 6 pin connector allows connections for fan con-
trol and external signals (fig. 6, page 5).
S:IN and S:OUT enable a signal that for example
lights up a lamp connected to S:OUT when there is
voltage to the S:IN.
Cable fuse
Sense + and sense - are inputs for sense cables to
measure and control the charging voltage at the
battery. This is useful for long battery charge
30 A
cables.
4445103656
Cable cross
Cable length
section
2
2.0 - 4.0 m
10 mm
2
3.0 - 6.0 m
16 mm
MT PL 1250
1.0 - 2.5 m
2
10 mm
2
2.0 - 4.0 m
16 mm
2
3.0 - 6.0 m
25 mm
PIN
Description
S:IN
Charging normally open relay PIN1
Charger OFF: PIN 1 & PIN 2 open
S:OUT
Charging common relay PIN2
Charger ON: PIN 1 & PIN 2 short
Sense+
Battery voltage sense for +
Charge compensation for long cabling
Sense-
Battery voltage sense for -
Charge compensation for long cabling
Night
FAN OFF by short PIN4
Reduced power, silent operation
ON/OFF
Remote charger ON/OFF
Main switch to ON/Remote: Charger OFF
by short PIN4 or remote control.
Main switch to SIGNAL: Charger ON by
short PIN4 or remote control.
Cable fuse
30 A
30 A
60 A
60 A
60 A

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Buttner mt pl 1250 powerline

Inhaltsverzeichnis