Interface Information / Wiring Diagrams
To insert BIS C-6002-...-ST11 processor into the serial PROFIBUS-DP, there are the terminal
X2 for the PROFIBUS input and the terminal X3 for the PROFIBUS output.
Bus station
green
A
red
B
...
Connect shield
to connector
housing
Output
5-pin male
X2, input
In case the processor is the last bus module in the chain, then only the incoming cable is con-
nected to X2.
The last bus module must terminate the bus with a resistor. In the case of the BIS C-602, this
can be realized in two different ways:
1. In the device by closing the switch S2
(factory standard is open)
Note: Output terminal must be closed
off with a screw cover in order to
maintain the enclosure rating.
2. Outside the device in a connector to socket X3. In this case the signal VP (pin 1) and
DGND (pin 3) should be brought out in order to connect the external resistor to the poten-
tial. Note: In this case S2 has to be open!
BIS C-6002-...-ST11
Interface Information / Wiring Diagrams
Connection for Read/Write Head 1
Connection for
Read/Write Head 1
Head 1
Head 2
1
2
3
4
5
6
7
8
S1
Head 1
Head 2
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
S2
Protection
ground PE
Supply
X1
X2
X3
voltage,
PROFIBUS-DP
digital input
Bus station BIS C-6002-...-ST11
1
VP
VP
1
green
A
2
A
2
3
DGND
DGND
3
red
B
4
B
4
Connect shield
to connector
housing
5-pin female
X3, output
S2
closed
open
X1, supply voltage, digital input
4
5
1
X2, PROFIBUS-
X3, PROFIBUS-
input (male)
output (female)
4
3
3
5
5
2
1
2
The ground connector should be connected to
earth directly or through a RC combination
depending on the system (potential counter-
poise).
When connecting the bus leads, make sure
that the shield has proper connection to con-
nector housing.
Bus station
A
B
Input
Terminating resistor
active
passive
E
57
3
Pin
.unction
2
Pin
.unction
4
1
n.c. = do not
connect