C60_2-028_823024_0401-e.p65
21
Description of
Output Buffer
(continued)
Please note the
basic procedure on
16 and 30...34
and the examples
on pages
35...45.
22
Description of
Output Buffer
(continued)
Please note the
basic procedure on
16 and 30...34
and the examples
on pages
35...45.
22
E
Function Description
Output buffer, configuration and explanation
Sub-
Meaning
Function Description
address
02
Start address
Address at which reading from or writing to the data carrier begins
Hex
(Low Byte)
(the Low Byte includes the address range from 0 to 255).
(Das Low Byte deckt den Adressbereich von 0 bis 255 ab).
or:
Program No.
Number of the program to be stored in the EEPROM in
conjunction with command ID 06
function (values between 01
or:
Program No.
Number of the program stored in the EEPROM for read or write
operations in conjunction with command ID 22
Mixed Data Access function.
or:
Initialization data
or:
Data
for writing to the data carrier
or:
Program data
for writing to the EEPROM.
or:
Parametering data for writing to the EEPROM.
03
Start address
Start address for reading from or writing to the data carrier (the High
Hex
(High Byte)
Byte is additionally used for the address range from 256 to 8,191)
or:
Initialization data
or:
Data
for writing to the data carrier
or:
Program data
for writing to the EEPROM.
or:
Parametering data for writing to the EEPROM.
(continued next )
Function Description
Output buffer, configuration and explanation
Sub-
Meaning
Function Description
address
04
No. of bytes
Number of bytes to read or write beginning with the start address
Hex
(Low Byte)
(the Low Byte includes from 1 to 256 bytes).
or:
Initialization data
or:
Data
for writing to the data carrier
or:
Program data
for writing to the EEPROM.
05
No. of bytes
Number of bytes to read or write beginning with the start address
Hex
(High Byte)
(the High Byte is additionally used for the range between 257 and
8,192 bytes).
or:
Initialization data
or:
Data
for writing to the data carrier
or:
Program data
for writing to the EEPROM.
06
Data
for writing to the data carrier
Hex
or:
Program data
for writing to the EEPROM.
...
Data
for writing to the data carrier
or:
Program data
for writing to the EEPROM.
Last byte
2nd Bit header
The data are valid if the 1st and 2nd bit header are identical.
or:
Data
for writing to the data carrier.
or:
Program data
for writing to the EEPROM.
for Mixed Data Access
Hex
and 0A
are allowed!).
Hex
Hex
or 22
for the
Hex
Hex
E