2 Remove the air inlet grille and the electrical panel
cover
l
WARNING
All connections must be made exactly as
shown in the wiring diagram on the inside of
the terminal block cover of the indoor unit.
Electrical
panel
Wiring diagram
3 Connect the U-shaped wire terminal to the terminals.
Match the colours/labels of the cables to the labels
on the terminal block, then screw the U-shaped wire
terminal of each cable firmly to the corresponding
terminal block. Refer to the serial number and wiring
diagram on the cover of the electrical panel.
a
CAUTION DANGER
– DO NOT SWITCH LIVE AND NEUTRAL
CABLES. Such a configuration is dangerous
and may cause the air conditioner to
malfunction.
– The refrigerant circuit can get very hot. Keep
the interconnection cable away from the
copper pipe.
4 Secure the cables with the corresponding cable ties.
The cable must not be slack and must not pull the
U-shaped wire terminal.
5 Refit the electrical panel cover and the front panel on
the indoor unit.
16
Air inlet grille
Connection diagram
Fig. 12
Magnetic ring
Pass the strap through the
hole in the magnetic ring
to secure it to the cable
INDOOR unit terminal blocks
Morsettiere unità INTERNA
(1)L
dalle morsettiere
from the terminal blocks
of the OUTDOOR unit
dell'unità ESTERNA
Installation
1 2 3
Fig. 13
(2)N
S
Fig. 14