Installation
d
It is PROHIBITED to install the indoor
unit in the following locations:
– oil extraction drilling or fracking areas;
– coastal areas with extremely salty air;
– areas with an atmosphere impregnated with
caustic gases, for example near thermal
sources;
– areas subject to strong power fluctuations,
for example factories;
– enclosed spaces (cabinets, etc.);
– kitchens with natural gas cooker hobs;
– areas used for storing gas or flammable
materials.
Please refer to the following diagram for wall and ceiling distances:
≥30 cm
≥200 cm
≥50 cm
m
CAUTION
If there are no refrigerant pipes:
When choosing the installation position, it is
recommended to provide a sufficiently large
space for the wall hole (see section "2.4.3
Preparation for connection pipes") in which
to insert the signal cable and the refrigerant
piping between the indoor and outdoor units.
The usual position for cables and pipes is on
the right side of the indoor unit (looking at the
unit).
However, the unit supports installation of
cables and piping both on the left and on the
right.
≥5 cm
≥50 cm
Fig. 3
11