2.4.4 Drainage pipe
The drainage pipe is used to drain the water from the
unit. Incorrect installation can cause damage to the unit
and other material damage.
a
CAUTION DANGER
– Insulate all of the pipes to prevent
condensate from forming, which could
cause water damage.
– If the drainage pipe is bent or not installed
properly, the water can escape and cause
the float switch to malfunction.
– In HEAT mode, the outdoor unit discharges
water. Make sure that the drainage pipe is in
a suitable area to avoid water damage and
slipping hazards caused by the discharge
water freezing.
– DO NOT pull the drainage pipe, as this could
detach it.
l
WARNING
A polyethylene pipe (outer diameter =
3.7-3.9cm, inner diameter = 3.2cm) is required
for this installation, which you can find in
hardware shops or from your local dealer.
Drainage
pipe
1 The drainage pipe must be connected downwards on
the external side.
2 A rigid PVC pipe widely available on the market (outer
diameter 26 mm) can be used for the already fixed
flexible drainage hose.
3 Connect the flexible hose to the drainage pipe,
then fasten it with tape. If the drainage pipe must
be connected inside, cover the pipe with a heat-
insulating material (polyethylene with specific 0.03
gravity and thickness of at least 9 mm) and fasten
it with adhesive tape to prevent the inlet air from
producing condensate.
Glue
Drainage
pipe
Pipe cover band
Fig. 11
4 After connecting the drainage pipe, check that the
water effectively comes out of the pipe and there are
no leaks.
5 The refrigerant pipe and the drainage pipe must
be thermally insulated to prevent water drips and
condensate.
6 Pass the flexible drainage hose through the hole in
the wall. Make sure that the water is drained in a safe
place where it cannot cause water damage or slipping
hazards.

2.4.5 Electrical connections

Cables with the following characteristics are required for
power supply and communication between the indoor
and outdoor units:
Power supplied
Indoor
from outdoor unit
unit
no.of cables/cross
section
140M
2 x 1mm
2
The indicated cross-sections are suitable for a wiring
length of up to 5 metres.
f
ATTENTION ELECTRIC DANGER
Before making electrical connections, turn off
the main switch of the system.
l
WARNING
WRITE DOWN THE SPECIFICATIONS OF THE
FUSES.
The air conditioner board (PCB) is equipped
with a fuse for overcurrent protection. Fuse
specifications are printed on the circuit board,
for example:
Indoor unit: T5A/250VAC
NOTE: The fuse is ceramic.
1 Prepare the cable for connection:
– Using a wire stripper, strip the rubber sheath at
both ends of the cable and expose approximately
15 cm of the internal conductors.
– Strip the insulation sheath at the ends of the
conductors.
– Using a crimping tool, crimp U-type wire terminals
to the ends of the conductors.
m
CAUTION
When crimping, clearly identify live cables ("L")
and other cables.
Signal from outdoor
unit
no.of cables/cross
section
+ G
2 x 0.2mm
2
15