14. Insert the elbow
15. Insert the screen
16. Carry out the steps described in the
"Preparing the filter vessel" section.
The filter medium is exchanged.

Replacing the timer battery

1. Make sure that the pump's power cable is
disconnected from the power supply.
2. Use a Phillips PH1 screwdriver to remove
the screws of the timer cover (turn
counterclockwise).
3. Remove the cover.
4. Lightly push down on one edge of the
battery to loosen it.
5. Remove the battery.
6. Replace the battery.
You can find the battery type needed in the "Technical data" section.
7. Replace the cover.
8. Screw in the screws clockwise.
The timer battery is exchanged.

Winter storage

1. Press the ON/OFF button
2. Pull the power plug of the pump
60