1)
Input source: Solar (only solar energy charges the battery)
Output source: Inverter Priority
① Both PV and utility are available
When PV power is higher than load power, it charges the battery and supplies extra power to the
load.
When PV power is lower than or equal to load power, PV stops charging the battery. Instead, it
supplies the load together with the battery.
When the battery voltage goes lower than or equal to the LVD point, the utility supplies the load, and
PV charges the battery.
② PV power is available, but the utility is not available
When PV power is higher than load power, it charges the battery and supplies extra power to the
load.
When PV power is lower than or equal to load power, PV stops charging the battery. Instead, it
supplies the load together with the battery.
When the battery voltage goes lower than or equal to the LVD point, only PV charges the battery.
www.solarv.de
the load as a supplement.