generally works when the indicator is ON solid.
Ensure that the battery connection is correct and the battery circuit breaker is turned
on first. And then, close the PV array and utility circuit breakers after the
inverter/charger running normally. Again, we won't assume any responsibility for not
WARNING
following the operation.
3)
Close the circuit breaker of the PV array.
4)
Close the circuit breaker of the utility input.
5)
After the AC output is normal, turn on the AC loads one by one. The inverter/charger typically works
as per the set mode. Do not turn on all the loads simultaneously to avoid protection due to a large
transient impulse current.
 When supplying power for different AC loads, it is recommended to turn on the load
CAUTION
 If the inverter/charger is not operating correctly or the LCD or the indicator shows
3 Interface
3.1 Indicator
Indicator
www.solarv.de
with a large impulse current. And then turn on the load with a smaller impulse
current after the load output is stable.
an abnormality, please refer to "Troubleshooting" or contact us.
Color
Green
Slowly flashing (0.5Hz)
Fast flashing (2.5Hz)
Green
Slowly flashing (0.5Hz)
Fast flashing (2.5Hz)
Green
Slowly flashing (0.5Hz)
Fast flashing (2.5Hz)
Green
Green
Green
Status
Off
No utility input
On solid
Utility connected, but not charging
Utility is charging
Utility charging fault
Off
No PV input
On solid
PV connected, but not charging
PV is charging
PV charging fault
Off
Inverter is off
On solid
Inverter standby or bypass
Inverter supplies power
Inverter fault
Off
Load off
On solid
Load on
Off
Relay disconnected
On solid
Relay connected
Remote control load on by cloud
On solid
platform or phone APP