Utility input
4)
Recommended wire size of the utility input and the circuit breaker is as below.
Model
UP2000-HM6021
UP2000-HM6022
UP3000-HM5041
UP3000-HM5042
UP3000-HM8041
UP3000-HM10021
UP3000-HM10022
UP5000-HM8042
Making the connection cable of the utility input:
Strip two connection wires of the utility input for about 10 mm.
Symbols
L
N
2.3 Determine the installation position
Step1: Remove mounting plate 1 and mounting plate 2 behind the inverter/charger with a
screwdriver.
Step2: Mark the installation position with the mounting plate 1. The distance between the
two mounting holes is 300mm.
www.solarv.de
Utility wire size
2
6mm
/9AWG
2
3.4mm
/12AWG
2
6mm
/9AWG
2
4mm
/11AWG
2
6mm
/9AWG
2
6mm
/9AWG
2
4mm
/11AWG
2
6mm
/9AWG
Abbreviation
LINE
Neutral
13
Circuit breaker
2P—40A
2P—16A
2P—40A
2P—25A
2P—40A
2P—40A
2P—25A
2P—40A
Name
Live wire
Neutral line
Copyright © 2021 SolarV GmbH All rights reserved
EN
Torque
1.2N.M
1.2N.M
1.2N.M
1.2N.M
1.2N.M
1.2N.M
1.2N.M
1.2N.M
Color
Brown/black
Blue

Werbung