Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connection; Installation; Factory Setting - Balluff BAE SA-OH-059-YI-DP02 Montageanleitung

Vorschau ausblenden Andere Handbücher für BAE SA-OH-059-YI-DP02:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BAE SA-OH-059-YI- ----
Photoelectric Sensors
Display elements
7
6
5 4
3
2
8
Fig. 3: Control panel of the amplifier
No.
Element
1
OLED
2
OUT
Yellow
3
Alarm
Red
4
OUT 2
Yellow
Green, alternating
with LED off at a
ratio of 10:1,
5
IO-L
1 s period
Green, static
6
SYNC
Orange, static
7
Button
Switch
+
Switch
8
Switch
-

Installation

The following mounting types of the sensor amplifiers are
available:
Simple clamp mounting on DIN rail with dimension of
DIN 35 mm or 15 mm.
Screw mounting by means of through holes for M3
screws.
Clamp mounting on DIN rail adapter by means of M3
threaded screws.
Place the device on the DIN rail adapter as shown. Connect
the cable according to the connection table.
Fig. 4: Mounting the amplifier
www.balluff.com
1
Function
Display status/values
Output 1 status
Alarm status /
Teach status
Output 2 status
IO-Link communication
is active
The device is ready for
operation
The device is ready for
operation
Synchronization
established
Multifunction button:
Back (in menu),
screen off (display),
Easy-Teach (hold down
for 3 s)
Scroll through menu
items or increase value
(Pressing and holding
the button causes the
values to scroll through
quickly)
Confirmation or
parameter transfer
Scroll through menu item
or decrease value
(Pressing and holding
the button causes the
values to scroll through
quickly)

Electrical connection

Electrical connection for the amplifier (4-pin connection only
on variant -S75G).
2
4
1
3
4-pin (supply)
Connection
Pin
1
VDC
4-pin
(supply)
2
I/Q
-S75G
(plug variant)
3
GND
4
C/Q
Brown
VDC
5-pin
(supply)
White
I/Q
-DP02
(cable
Blue
GND
variant)
Black
C/Q
Pink
TEACH
1
LED+
3-pin
(sensor)
3
FT+
(all versions)
4
GND

Factory setting

– Mode: SIO mode
– Operating mode: Standard Power, Standard
Sensor, Standard Speed, Sync Mode Off
– PIN 4/black: PNP switch output
(in IO-Link mode: Push-Pull)
– PIN 2/white: Inactive (PNP)
– Pink on -DP02: Inactive (PNP)
Shielding and cable routing
The sensor cable is shielded and should not be extended.
For IO-Link operation, the maximum supply cable length is
20 m.
4
1
3
3-pin (sensor)
Signal
L+ (operating voltage+
SIO 15...30V,
IO-Link 18...30V)
Max. current consumption:
45mA
Digital input /
Digital output
L- (operating voltage- 0V)
IO-Link communication /
digital output in SIO mode
L+ (operating voltage+
SIO 15...30V,
IO-Link 18...30V)
Max. current consumption:
45mA
Digital input /
Digital output
L- (operating voltage- 0V)
IO-Link communication /
digital output in SIO mode
External teach (input)
Transmitter (LED)
Receiver (phototransistor)
0V / cable shield
english