Network interface
Installation
Fasten the module with 2 M6 screws and a maximum
tightening torque of 3 Nm using the mounting holes.

Electrical connection

Power supply
NOTICE
Unwanted voltage dips
Non-separated electric circuits of the power supplies for
sensor and actuator can lead to unwanted voltage dips
of the sensor supply when switching actuators.
► Fuse the power supplies for sensors and actuators
separately.
► Make sure that the power supply of the device is
sufficiently dimensioned to cover start-up and peak
currents and design the fuse protection concept
accordingly.
For UL: Observe cable requirements and power
supply requirements (see chapter
UL requirements)!
– Establish power supply of sensor/bus and
actuator via a separate power source if possible.
– The total current for the sensor and actuator
supply must not exceed 16 A each.
www.balluff.com
Electrical connection (continued)
M12 plug
(L-coded, with FE)
Top view of M12 plugs (left) and sockets (right)
Pin
Signal
Description
1
+24 V US
Module/sensor voltage
2
GND UA
Actuator supply
3
GND US
Sensor supply
4
+24 V UA
Actuator supply
5
FE
Functional earth
M12 socket