DANGER
Danger from malfunction!
In the event of a battery error
message/contamination message,
the smoke alarm device may
only continue to provide its reliable
warning performance for max. 60
days .
f Ensure that the device is replaced
before the remaining 60 days have
passed .
Battery error message
A battery error message is triggered
when the device starts using its energy
reserves. During a battery error mes-
sage, a single tone will sound every 90
seconds (see chapter 17 "Alarm and
alert tones" on page 83). Proceed as
follows:
(1) Press testing/stop button to turn off
the battery error message for
24 hours.
(2) Replace the device.
72
Operating Manual: XSD200 - Smoke Alarm Device with Radio Link
Contamination message
A contamination message is trig-
gered when the readjustment of the
detection electronics is no longer pos-
sible due to heavy soiling. During the
c o n t a m i n a t i o n m e s s a g e , a d o u -
ble tone will sound every 90 seconds
(see chapter 17 "Alarm and alert tones" on
page 83). Proceed as follows:
(1) Press testing/stop button to turn
off the contamination message for
24 hours.
(2) Replace the device.
Alarm without cause of fire
An alarm without fire is triggered under
the following circumstances:
Regular dust formation in
living spaces with textiles prone
to accumulate dust (e.g. carpets,
clothing, blankets and pillows)
Pollen, construction,
sanding or fine dust
Insects or micro-organisms
that have overcome the insect
EN
barriers of the device
Strong cooking, water and/or
frying fumes and room, fragrance
and insect repellent sprays
Extreme temperature fluctuations
or very strong electromagnetic
radiation in close proximity
influence the device
Cigarette smoke only trig-
gers an alarm when it is in
the immediate vicinity and
in higher concentration.
You can take the following corrective
measures:
f Stop the alarm (see chapter 11.1
"Alarm stop" on page 70).
f Ensure that there is adequate venti-
lation at the installation location.
f Carefully and regularly clean the
device, e.g. using a vacuum cleaner.
f Inform neighbours about an alarm
without a cause of fire, so that
they do not falsely inform the fire
brigade.
EN
Operating Manual: XSD200 - Smoke Alarm Device with Radio Link
EN
EN
12.2 Troubleshooting
Problems can occur during activation,
installation and operation under the fol-
lowing circumstances:
Devices not or no longer
in the learning mode
Radio group not or no longer
in the learning mode
No wireless connection, although
the device and the radio group
are in the learning mode
Defective device in a radio group
You can detect a problem from the light
signal on the LED (see chapter 18 "Light
signals" on page 87).
Device not or no longer in
Device not or no longer in
the learning mode
the learning mode
If a device cannot be connected to a ra-
dio group, and its LED signal light does
not flash yellow, it can be that the de-
vice is not or is no longer in the learn-
ing mode. To troubleshoot, proceed as
73