USER ENROLLMENT PROCEDURE
1
TO START ENROLING A USER'S FINGERPRINT, BUTTON
1
ON THE CONTROL UNIT SHOULD BE PRESSED.
The blue LED will start blinking.
2
ADMINISTRATOR FINGERPRINT IS VERIFIED FIRST.
For security reasons an admnistrator fingerprint is needed to start
the user enrolment procedure. When the administrator finger will
be recognized, the green LED will flash, accompanied by a beep.
If a non-administrative finger will be placed on the sensor, the
device will not react and the blue LED will keep flashing.
OPTIONAL STEP: ASSIGNING RELAY 2
THIS STEP SHOULD BE SKIPPED IF THE FINGERPRINT SHOULD ONLY OPEN THE DOOR
Follow the steps on the previous page.
3
BLUE AND GREEN LEDS WILL FLASH ALTERNATELY.
THE FINGER SHOULD BE PLACED ON THE SENSOR
UNTIL THE GREEN LED FLASHES AND A SHORT BEEP IS
HEARD, WHICH MEANS THE FINGERPRINT HAS BEEN
ENROLLED.
IF A DAMAGED OR AN EXTREMELY NON-
PROMINENT FINGERPRINT WILL TRY TO BE
ENROLLED, THE RED LED WILL FLASH 5 TIMES,
ACCOMPANIED BY 5 BEEPS AND THE OPERATION
WILL BE TERMINATED. A QUALITY, CLEAN AND
SUFFICIENTLY MOIST FINGERPRINT SHOULD BE
CHOSEN FOR ENROLMENT.
96
BLUE
A
GREEN
1x
BLUE
1 x
1 x
BLUE
GREEN
U
GREEN
1x
USER DELETION PROCEDURE
1
TO DELETE A USER'S FINGERPRINT, FIRST BUTTON
THE CONTROL UNIT SHOULD BE PRESSED.
The blue LED will start blinking.
2
ADMINISTRATOR FINGERPRINT IS VERIFIED FIRST.
For security reasons an admnistrator fingerprint is needed to start
the user deletion procedure. When the administrator's finger will
be recognized, the green LED will flash, accompanied by a beep.
If a non-administrative finger will be placed on the sensor,
the device will not react and the blue LED will keep
flashing.
3
1 x
GREEN AND RED LEDS WILL FLASH ALTERNATELY.
THE FINGER THAT NEEDS TO BE DELETED SHOULD
BE PLACED ON THE SENSOR.
Successful deletion will be confirmed by 3 flashes of the
orange LED, accompanied by three beeps.
If a non-stored fingerprint will be placed on the sensor, the
device will not react. Green and red LEDs will keep flashing.
FACTORY RESET
1
BUTTON
R
ON THE CONTROL UNIT SHOULD BE
PRESSED AND HELD FOR 10 SECONDS. AFTER THIS
PERIOD VIOLET LED WILL FLASH 5 TIMES AND 5
BEEPS WILL BE HEARD.
All fingerprints will be deleted from the database and the
device will have the factory settings restored. All paired
remote controls will be unpaired.
EN
2
ON
BLUE
A
GREEN
1x
BLUE
RED
GREEN
U
ORANGE
3x
VIOLET
5x