TEHCHNICAL DATA
Fingerprint capacity: 166
Power supply voltage: 8-30 V, AC or DC
2 relay outputs (in combination with the BBX control unit 1 relay output)
Maximum current on the relay: 3 A
Relay triggering time 2 s
Maximum power: 1.8 W in analog mode, 2.5 W in Wi-Fi mode
Fast fingerprint recognition: <1,2 s
Operating temperature range: from -30 ºC to +80 ºC
Maximum environmental humidity: 100 % IP65
Fingerprints will remain in the memory in the case of power failure.
Area capacitive sensor FPC1011F3
User interface: 3-colour LED, beeper, buttons on the control unit or remote control
CONTROL UNITS AND WAYS TO OPERATE A FINGERPRINT READER
Our fingerprint readers can be installed in different configurations with different control units:
OPTION 1: Fingerprint reader + door leaf control unit
OPTION 2: Fingerprint reader + DIN rail control unit
OPTION 3: Fingerprint reader + mini control unit BBX
COMPONENTS AND THEIR FUNCTIONS
EXTERNAL UNIT - FINGERPRINT READER
1
2
3
88
MULTICOLOR LED
1
It provides different signals about
the status of the device and operations.
FINGERPRINT SENSOR
2
Always in standby mode. When a suitable fingerprint is
placed on it, the door will open immediately.
3
It provides sound signals to complement
the LEDs during operations.
CONTROL UNIT INSTALLED IN A DOOR LEAF - option 1
MINI CONTROL UNIT BBX - option 3
BEEPER
1
Analog mode: ADD ADMINISTRATORS OR USERS
Wi-Fi mode: SWITCH ON FREE PASSAGE
2
Analog mode: DELETE USERS
Wi-Fi mode: SWITCH ON BLUE LIGHTING
3
Performs FACTORY RESET.
To access the button, unscrew the bolt first.
DIN RAIL CONTROL UNIT - option 2
Performing functions with a remote control.
RESET »R« BUTTON
On position 10.
Performs FACTORY RESET.
RESET BUTTON
The factory settings recovery
button is located under the
connector.
EN
BUTTON
1
BUTTON
2
BUTTON
R