Fit the sensor holders over the individual mounting bolts and tighten securely with the
locking nut.
5.
Apply the coupling pad to the sensors with the adhesive side facing down ().
Alternatively coat the contact surfaces with an even layer of coupling gel (approx.
1 mm (0.04 in)). going from the groove through the center to the opposite edge.
 18
Coating the contact surfaces of the sensor with coupling gel (if there is no coupling
pad)
6.
Insert the sensor into the sensor holder.
7.
Fit the sensor cover on the sensor holder and turn until the sensor cover engages with a
click and the arrows (▴ / ▾ "close") are pointing towards one another.