EA01368D
8.2.5
Sensor holder with strapping bands (small nominal diameters)
(Prosonic Flow P, W)
Can be used for
• Measuring devices with measuring range DN 15 to 65 (½ to 2½")
• Mounting on pipes DN > 32 (1¼")
Procedure:
1.
Disconnect the sensor from the sensor holder.
2.
Position the sensor holder on the measuring pipe.
3.
Wrap the strapping bands around the sensor holder and measuring pipe without
twisting them.
 3
Positioning the sensor holder and mounting the strapping bands
1
Sensor holder
4.
Guide the strapping bands through the strapping band locks.
5.
Tighten the strapping bands as tightly as possible by hand.
6.
Set the sensor holder to the desired position.
18