Endress+Hauser Proline Prosonic Flow P 500 Installationsanleitung Seite 12

Austausch sensor, sensorhalterung, installations set
Vorschau ausblenden Andere Handbücher für Proline Prosonic Flow P 500:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EA01368D
6.
Project and draw the center line onto the rear of the measuring pipe.
7.
Mark the drill hole on the rear center line.
8.
Cut out the second drill hole and prepare holes for welding in the sensor holders
(deburr, clean).
9.
Insert sensor holders into both drill holes. To adjust the welding depth, both sensor
holders can be secured with the special tool for regulating the insertion depth
(optionally available ) and then aligned with the path rod. The senor holder must be
flush with the inside of the measuring pipe.
10. Spot-weld both sensor holders. To align the path rod, screw both guide bushes into the
sensor holders.
11. Weld in both sensor holders.
12
a
Endress+Hauser