Operationg manual - English

5.4 Installation suggestion for hygienic drainage

All connections that have to be in connection
with the waste water
a free outlet according to DIN EN 1717 section 9
can be established, regardless of whether the
siphon connection is higher or lower than the
connection to the machine. Ideally, the siphon
with inlet funnel (on site) is prepared as a floor
drain (see Fig. 5.4.3).
Important installation information for water-cooled models:
This device has DVGW approval!
To avoid contamination of the drinking water due to backflow, the cooling water hose with free outlet
according to DIN EN 1717, Section 9 must be connected to the drainage line.
DIN EN 1717, Section 9: Free discharge over a drainage object
The free outlet over a drainage object must be completely
separated or through ventilation openings.
Failure to comply with the requirements described in Section 9 will invalidate the DVGW approval!

5.5 Optional condensation water pump Installation condition

Fig. 8: Principal illustration of application
with optional condensation water pump
Operating-Manual-CubeLine-v.01
Fig. 7: Installation instructions for free discharge over
a drainage object according to DIN 1717 section 9 of
the cooling water.
The pump has a maximum of 300W therefore
the dimensions specified in Fig 5.4 must not be
exceeded:
▪ Height difference max 2,50m
▪ Distance between ice maker and drain max 15m
IMPORTANT:
Always make sure that there is a free outlet over
the funnel siphon.
84
Cooling water hose
(DN 10)
Free spout:
larger than ø siphon,
at least 20 mm
01/2021