5.3 Installation water cooled machine (Version W)

Water-cooled ice makers can be installed without observing minimum clearances and without considering fresh air
circulation; however, the distance for the connection hoses must be maintained from the rear of the machine to the
wall:100 mm by IC130 and 50 mm by IC135.
Network-
Power supply
230 V, 50 Hz
Fresh
Water
connection
Ø ¾"
Fig.5: Rear view IC130 EL
Please note the figures 5, 6 and 7!
5.3.1 Please connect the enclosed inlet hose (DN 8; ¾"–screwing) with the fresh water connection Ø ¾"
and with the water tab (cold water-/ fresh water inlet). Make sure that the rubber sealing is well in place.
By IC130:
5.2.2 Fasten one drain hose (DN 20) to the residual
water connection of the machine, fix it with the hose
clamp and route it to the sewage network (see
chapter 5.4). Make sure that the hose always runs
with a slope and does not have any kinks.
5.2.3 Attach the other drain hose (DN 20) to the
machine's defrost water connection, fix it with the
hose clamp and route it to the waste water network
(see chapter 5.4). Make sure that the hose always
runs with a slope and does not have any kinks. If the
drain hose does not have a sufficient slope, the
storage container may overflow and water damage
may result.
5.3.4 Fasten the drain hose (DN 10) to the cooling water connection of the machine, fix it with the hose clamp and
route to the sewage network (see chapter 5.4). Make sure that the hose always runs with a slope and does not
have any kinks.
Operating-Manual-CubeLine-v.01
Defrostwater
connection
Residual water
Ø 20 mm
connecion
Ø 20 mm
Cooling
water
connection
Ø 10 mm
83
Cooling
water
connection
Ø 10 mm
Fresh Water
connection
Ø ¾"
Communication
socket 1
Defrostwater
connection
Ø 20 mm
Fig.6: Rear view IC135 ECL
By IC135:
5.2.2 Fasten the long drain hose (DN 20) to the
residual water connection on the machine and fix it
with the hose clamp.
5.2.3 Fasten the shorter hose section (DN 20) to the
Defrost water connection of the machine and fix it
with the hose clamp, attach the hose from the
residual water drain to the Residual water connection
and route to the waste water network (see chapter
5.4). Make sure that the hose always runs with a
slope and does not have any kinks. If the drain hose
does not have a sufficient slope, the storage
container may overflow and water damage may
result.
Residual
water
connecion
Ø 20 mm
Network-
Power supply
230 V, 50 Hz
Communication
socket 2
01/2021