7.4 Trouble shooting

If ongoing operation is stopped due to a fault, the on / off button flashes. Remove the front panel (cover and front
panel for IC135 models) in order to read the error message in the display of the control element.
When the cause of the fault has been eliminated, the fault message in the display can be closed by pressing the on
/ off button once. If the error message occurs again immediately after it has been closed, contact your specialist
dealer or WESSAMAT service.
Error codes are only displayed with the IC250 ice maker variant!
Malfunction
Display:
Error code 7
Fault high pressure switch
trips
Display:
Error code 5
Fresh water supply fault
active for more than 2 minutes
Display:
Error code 1: Module Upper
tub upward
Error code 2: Module
downward, tub down
Error code 3: Module below,
tub up
Error code 4: Module below,
tub down
Fault tub does not reach the
upper or lower limit switch
Display:
Error code 6:
Defrost fault active for more
than 15 minutes
IC135 ECL, ECW only
Display:
Rocker malfunction
Ice maker does not run even
though the power plug is
plugged in.
Ice maker does not run
although it is switched on.
Ice maker does not produce
ice.
Operating-Manual-CubeLine-v.01
Cause
Ambient temperature too high.
The condenser is dirty.
Fresh water not connected or the tap
not turned on.
Clogged water inlet or filter.
Ice blocks the mechanics.
Defect in the mechanics.
Motor coupling no longer functional
Ambient temperature too low.
Ambient temperature too high.
Ice blocks the mechanics.
Defect in the mechanics.
Machine has no voltage from the
mains.
In air-cooled machines, the air
circulation is insufficient
The condenser is dirty.
The water supply is interrupted in
water-cooled machines.
Storage tank is full (storage tank
thermostat has switched off).
Storage tank thermostat has switched
off although the storage tank is not filled
with ice.
Ambient temperature too low.
The water level probe has a moisture
bridge.
Production time is too long, injection
100
Measures for troubleshooting
Lower the ambient temperature or
change location if necessary.
Clean the condenser.
Connect fresh water or open the tap.
Clean the water inlet or filter.
Switch off the machine, remove the ice
by hand or, if necessary, wait until the
ice cubes have defrosted.
Clean the injection plate.
Reduce production time (see Chapter
6.2).
Contact specialist dealer or
WESSAMAT service.
Replace the motor coupling, contact
your specialist dealer or WESSAMAT
service.
Increase the ambient temperature or
change location if necessary.
Lower the ambient temperature or
change location if necessary.
Switch off the machine, remove the ice
by hand or, if necessary, wait until the
ice cubes have defrosted.
Clean the slide and rocker of the combi
module.
Contact specialist dealer or
WESSAMAT service.
Check socket.
Check the distances between the
machine and the side walls and to the
rear, ensure that the machine is
properly ventilated.
Clean the condenser.
Open the water inlet.
Ice maker will automatically resume ice
production when enough ice has been
removed from the storage bin.
Check storage tank thermostat.
Increase the ambient temperature or
change location if necessary.
Dry the water level probe.
Allow injection nozzles to thaw, reduce