8 Connecting to Ceramic Flues

The information provided in advance regarding assembly instructions and installation regulations are still valid (see
distances, thermal insulation, flue pipe connection).
The appliances are especially suitable for installation with ceramic flues. However, proper functioning of the heating
system can only be guaranteed if the following points are observed:
- Installation of a start-up flap (start-up slide) directly connected to the chimney;
- Calculation of the ceramic flue;
- Use of suitable materials;
- Compliance with the maximum flue lengths;
- Installation of a direct or preheating flue;
- Compliance with the prescribed unobstructed area of the air grids.
The ceramic flue must be calculated in compliance with the maximum flue lengths specified, and in line with the
Technical Regulations of the Furnace and Air Heating Construction Trade as well as with the prevailing structural
designs.
Specifications for calculating the flue dimensions
Appliance type
Flue gas mass flow [m(g/s)]
65x S
75x S
75x39 SII
75x51 SII
80x64 S / 80x64 SII
97x S
120x45 S
55x55x S
69x49x57 S
89x49x45 S / 89x49x57 S
63x40x42 S / 63x40x51 S
48x51x51 S3
48x72x51 S3
75x35x45 S3
64x33x51 S3
VUUR DRIE 80
VUUR DRIE 60
The flue gas temperatures at the appliance connection are average temperatures measured over the duration of
combustion.
Maximum length of the ceramic flues made of fireclay
Appliance type
65x S
75x S
75x39 SII
75x51 SII
80x64 S / 80x64 SII
97x S
120x45 S
55x55x S
69x49x57 S
89x49x45 S / 89x49x57 S
63x40x42 S / 63x40x51 S
48x51x51 S3
48x72x51 S3
75x35x45 S3
64x33x51 S3
VUUR DRIE 80
VUUR DRIE 60
Flue gas temperature at the
appliance connection [°C]
7,3/7,7/6,8
8,1/7,7
7,3
13,07
8,28/8,43
9,9
14,88
7,5
12,42
10/10,5
7,65/12,0
11,96
17,32
11,49
11,86
14,8
11,4
Flue length [m]
Discharge pressure at the
4
4
4
4
4
4
4
4
4
4
3,5
4
4
4
4
4
4
FIREPLACE INSERTS / SLIDING DOOR
283/298/317
313/300
286
252
312/291
274/288
254
330
260
307/297
230/283
231
270
263
261
254
276
nozzle [Pa]
12
12
12
12
12
12
12
14
12
12
12
12
12
12
12
12
12
25
Required discharge pressure
at the nozzle [Pa]
12
12
12
13
12
12
13
14
12
12
12
12
12
12
12
13
12
Flue gas temperature after
heat exchange [°C]
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190
190