FIREPLACE INSERTS / SLIDING DOOR
6.8

Ornamental beam

6.9

Convection air duct

14
13
6.10

Ceiling above the fireplace insert

8
11
6.11

Flooring in front of the fireplace insert

The flooring in front of the fireplace insert must be made of non-combustible material. Minimum dimensions of this
non-combustible surface must be a minimum of 50 cm to the front and a minimum of 30 cm to the sides.
6.12

Fire protection in the radiation area

The minimum distance (as specified in Technical Data) to components made of combustible building materials or to
combustible components and to built-in furniture must be maintained from the front, the top and the sides of the firebox.
If radiation protection is fitted, which is ventilated on both sides, half this distance is sufficient.
Examples of the radiation area:
18
www.austroflamm.com
11
• Ornamental beams
porting frame
...
24
-
the ornamental beam is not part of the building;
-
the spaces between the beam and the cladding are sufficient to prevent heat
from accumulating;
-
the ornamental beam is not within the radiation area of the open fireplace.
Direct anchoring with thermal bridges is not permitted.
(F) Expansion joint
(23) Supporting frame
F
23
• The cross section of the air inlet duct
must each be at least 700 cm².
• A minimum of 200 cm² of the air inlet and air outlet apertures must not be
sealable.
• There must be no combustible building materials such as a wooden ceiling
and no built-in furniture with a range of 30 cm adjacent to, and 50 cm above
the air outlet apertures
If the cavity above the fireplace insert extends to the ceiling of the room
(8), the ceiling must be protected if:
- it consists of combustible materials;
- it serves as a load-bearing element;
• the thermal insulation layer (dimension G) has to be installed according to
national installation standards
are permitted in front of the cladding
(24)
of the open fireplace at a distance of at least 1 cm provided
(23)
(24) Ornamental beam
(11) Cladding
(13).
(11).
18
(11)
and the air outlet aperture
(14)
english
EN
and the sup-
(13)