6.2.2 ASSKEA M30
Plus
Error
Device does
not start.
Device does
not charge.
Diminished
flow rate
Insufficient
flow rate
LED display
Possible causes
LEDs do not illuminate
Battery is discharged.
LED blinks red
Battery is discharged and invalid
input voltage
Temperature of the battery too high for
LED blinks red
charging
LED illuminates green
Battery is defective.
LED blinks red
Invalid input voltage
LED blinks
Device is overheated and is only running
green / yellow
in curbed operation.
LED illuminates
External bacterial filter blocked
green / yellow
Internal bacterial filter blocked
LED illuminates green
leak in the tubing system or in the canister
system
LED illuminates red
Battery is weak.
LED does not
illuminate
6 Troubleshooting
Remedy
Connect the power supply unit for
charging or operating.
Connect the correct power supply unit;
check the power supply.
No measure required, automatic resump-
tion of charging when battery has cooled
down.
Please contact Service!
Connect the correct power supply unit,
check the power supply.
Switch off the device and allow it to
cool down.
Replace the external bacterial filter.
Please contact Service!
Check that secretion canister lid and
tubing connections are tight and no
leakages are apparent.
Connect the power supply unit for
charging or operating.