INNOVATIVE ORBITAL SOLUTIONS

5. USB key

USB key root :
SAXX
software
Data
acquisition
files
Folder « ALARM » :
Folder « Recipe » :
Folder SAMP01 :
Join
experience
It contains only one CSV file. This file lists the alarms that have occurred with the
date and time of each alarm.
SAXX configuration back-up (language, units, user list, etc.)
Welding programs back-up
Back-up of the source calibration (current, voltage, also contains
information of the Wifi router)
Back-up the calibration of gas flow meters
Back-up the "Counter" screen of the "Settings" menu
Each file corresponds to a weld. The SAXX numbers them from 0 to 999 then
reverts to 0 overwriting the old files.
We recommend using the "Weldreport" software (available on the SAXX USB
stick) to read and use these files.