Herunterladen Diese Seite drucken

AXXAIR SAXX-210 Originalbetriebsanleitung Seite 68

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 95
INNOVATIVE ORBITAL SOLUTIONS
Level and overlap :
If mode with wire :
Operator dynamic: zero by default, that means parameters will not be modifiable during the welding
(except in dynamic mode). If you put a value different from zero, all parameters will be modifiable
(even in welding mode and even with operator level) in the limit of the percentage you have entered.
Join
experience
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
English
Level and overlap parameters:
- You have on this screen all the parameters
used during rotation around the tube:
currents, pulse times, advance speed, wire
speed, angle and direction.
- All these parameters can be freely adjusted
for each level.
- Use buttons on the left of the screen to
pulse or not the parameter.
- Total of level angles should be 360°. Then
you have the overlap screen.
This window appears on the overlap screen:
The parameter « Delay stop wire » is the time
between the beginning of the overlap and the
end of the wire feeding.
Wire back action: At the end of the wire
feeding, the wire goes back during the time
« wire back action ».
Downslope: This is the time during which the
welding current passes from the high current
of the overlap level to the "Postwelding"
current value.
Postwelding: It allows us to maintain a
current for a given time in order to prevent
any heat shock to the electrode or the bead
we have just made.
Postgas time: We continue to apply gas to
the end of the bead in order to prevent any
oxidation while the latter is cooling.