Herunterladen Diese Seite drucken

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 95
INNOVATIVE ORBITAL SOLUTIONS

4.9. Alarms

Screen alarm
0A
ALL STOP
Current source alarms
1D
Inverter - General
1E
Inverter - Temperature
Welding voltage alarms
2B
Low welding voltage
2C
Ignition aborted
2D
High welding voltage
2E
Welding voltage drift
Gas alarms
3A
External gas - minimum
flow
3B
Internal gas - minimum flow
3C
External gas - minimum
percentage
3D
External gas - maximum
percentage
3E
Internal gas - minimum
percentage
3F
Internal gas - maximum
percentage
Rotation axis board
4A
Rotation axis -
Communication
4B
Rotation axis - Current
4C
Rotation axis - Voltage
Join
experience
Button « ALL STOP » has been used during cycle
Switch off the power source, wait 20s and switch it on. If alarm is
still active, contact AXXAIR.
While under intensive use (> to duty cycle) the thermal protection
turns on. Let it cool down.
Welding voltage <4V. Tube-electrode distance too low.
Power source failed to create electrical arc. Tube-electrode
distance too high / welding cables unplugged or reversed.
Electrode deteriorated / gas shielding not correct / ceramic ground
cable not connected
Welding voltage >25V. Tube-electrode distance too high.
Only with closed head: welding voltage has increased or
decreased of more than 3 Volts, which means there is a problem:
tube ovality or other.
Torch gas flow < 4 l/min
Internal gas flow < 1 l/min
Only if alarm activated on adjustment menu: torch gas flow inferior
to tolerated percentage compared to programed value.
Only if alarm activated on adjustment menu: torch gas flow
superior to tolerated percentage compared to programed value.
Only if alarm activated on adjustment menu: Internal gas flow
inferior to tolerated percentage compared to programed value.
Only if alarm activated on adjustment menu: Internal gas flow
superior to tolerated percentage compared to programed value.
Switch off the power source, wait 20s and switch it on. If alarm is
still active, contact AXXAIR.
Check name of machine into the program and into the serial
number plate of the machine connected.
Check the machine cables. It can be a problem onto the motor, or
speed/position sensor.
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
English
Power source has an autodiagnostic system
in order to detect eventual problems.
You can not weld if an alarm is active.
If an alarm appears during welding cycle,
power source stops welding and switches to
postgas step.
Press the arrows to select one alarm and then
the button « info » in order to have more detail
about this alarm.
Solve the problem and then press the "ACQ"
button. If problem has disappeared, the
message becomes green.
330B Route de Portes Les Valence - ZI Les Bosses - 26800 Etoile sur Rhône
Tél: +33 475 575 070 - Fax: +33 475 575 080 - commerce@axxair.com - www.axxair.com
- 82 -

Werbung

loading

Diese Anleitung auch für:

Saxx-300