Herunterladen Inhalt Inhalt Diese Seite drucken

Lenze EMB934 Serie Betriebsanleitung Seite 90

Versorgungs− und rückspeisemodul
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4
Mechanical installation
Regenerative power supply modules EMB9341 and EMB9342
Mains filter mounting
Fig. 4−2
All dimensions in millimetres.
Installation steps
How to mount the mains filter:
1. Drill holes into the mounting plate of the control cabinet for screwing the mains
filter:
– The mains filter must be mounted near the regenerative power supply module
(from a connecting cable length of 30 cm, shielded cables must be used).
– The condition of the wall and the mounting material must provide for the
mechanical connection to be long−lasting.
– Observe dimensions and distances of the drill holes .
– Allow a free space of 100 mm at the top and at the bottom.
– Vertical mounting position with mains connection on the top.
2. Screw the mains filter and the mounting plate of the control cabinet together.
– Provide for long−lasting mechanical connections.
90
105
7
PE
L1
L2
L3
LIN E
LO AD
PE
L1 ' L2 ' L3 '
92
135
Dimensions of mains filter EZN3A0088H024 for EMB9342
l
200
230
EDBMB9340 DE/EN/FR 12.0
9340vrm018