Lenze EMB934 Serie Betriebsanleitung Seite 119

Versorgungs− und rückspeisemodul
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

K1
L1
L2
L3
N
PE
F1...F3
Z1
Fig. 5−9
Wiring
(
Stop!
ƒ
ƒ
EDBMB9340 DE/EN/FR 12.0
Regenerative power supply module EMB9343
L1
L2
L3 PE
F4
F5
L1
L2
L3
PE
X4 X10
L1A L1B
+UG
-UG
9343
E1 39 A1 A2 59
L3' L2' L1' L3.2 L2.2 L1.2
Central supply for DC bus connection of several drives and internal mains synchronisation
Z1
Mains filter A
Z2.1 ... Z2.n
Controllers in the drive system
F1...F3
Mains fuse
K1
Main contactor
F4...F9
DC−bus fuses
Bolt the cables to X4 (blue) and X10 (red) with a distance of at least 5.5 mm.
The cables L1A, L1B, X4 and X10 are additional electrical connections
between the mains filter A and the regenerative power supply module
EMB9343. They must be bolt at the regenerative power supply module at
the threaded bolts with the same designation.
l
Electrical installation
Power connections
F6
F7
L1
L2
L3
PE
+UG
-UG
Z2.1
PE U V W
28
39
59
Ax
M
3~
PE
5
F8
F9
L1
L2
L3
PE
+UG
-UG
Z2.n
PE U V W
28
39
59
Ax
M
3~
PE
9340vrm006b