Danger from noise
hearing damage
Prelonged unprotected work with the device may
cause hearing damage.
- Always wear ear-muffs .
Danger caused by materials and other substanc-
es
Contact, inhalation
The emissions of the machine may cause damages
to health.
- Only use the motor driven machine outdoors.
Fire, explosion
m Fuel is flammable.
- During work and refuelling smoking and open
flames are prohibited.
In case of emergency
In case of a possibly occuring accident take the nec-
essary first aid steps as appropriate and obtain quali-
fied medical aid as quickly as possible.
If you obtain aid please give the following infor-
mations:
1. Where did it happen
2. What happend
3. How many injured
4. Type of injury
5. Who is reporting!
6.

Technical data

Generator
IP class
Continous power P
(S1) (230
nenn
V) W
Maximum power P
(S2 2 min)
max
(230 V) W
Rated voltage U
nenn
Rated current I
nenn
Frequency F
nenn
Drive engine design
Displacement cm
3
Maximum power (motor) kW /PS
Fuel
Tank capacity l
type of motor oil
Amount of oil (approx.)
Consumption at full load l/h
Weight kg
Performance factor cos φ
Performance class
Temperature max
C
°
Max. altitude
Spark plug
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Digital Inverter
IP23M
1600
2000
2 x 230 V~
7 A (230 V)
50 Hz
4 stroke 1 cylin-
der air colled
105,6
2,1 / 2,86
unleaded (E5)
3,2
10W30 / 15W40
350 ml
1,07
20,4
1
G1
40
1000 m
A7RTC
22 | GB
Subject to technical modifications!
Operating mode S1 (continuous operation)
The machine can be continuously operated with the
quoted power output.
Operating mode S2 (temporary operation)
The machine may be temporarily operated with the
quoted power o utput. Afterwards the machine must
be stopped for a while to prevent it from overheating.
Information concerning noise emission measured ac-
cording to relevant standards:
Sound pressure L
= 75 dB(A)
pA
Sound power L
= 95 dB(A)
wA
Uncertainty K
= 3,0 dB
pA
Wear ear-muffs.
The impact of noise can cause damage to hearing.

7. Before starting up

m ATTENTION!
Always check before starting the engine:
• Check the fuel level and top it up if necessary
- the tank should be at least half filled
• Make sure that the generator has sufficient ventila-
tion
• Make sure that the ignition cable is secured to the
spark plug
• Disconnect possibly connected electronical device
from the generator
• Condition of the air filter
• Condition of the fuel lines
• The external bolt connections for tightness
Attention! Fill the oil before first use.
Before each use, check the oil level with the engine
switched off and on a level surface. Use the highest
quality four-stroke oil or an HD oil with the same level
of quality.
SAE 10W-30 is recommended for general use at all
temperatures.
Checking the oil level, fig. 9
Remove the engine cover (Fig. 6-7)
Remove the oil filler cap (D) and wipe the dipstick
clean.
Check the oil level by inserting the dipstick into the
filling nozzle without screwing the cap on.
If the oil level is too low, refill with the recommended
oil up to the lower rim of the oil filling nozzle.
Filling with fuel
• To refuel - cap (2) open counter clockwise.
• Fill fuel tank in
• Closing tank - tank cap (2) clockwise.
Recommended fuel
Unleaded regular gasoline with a research octane
number of 91 or higher is required for this engine.
Use only fresh and clean fuel.