Herunterladen Inhalt Inhalt Diese Seite drucken

VERDER VERDERFLEX VF10 Bedienungsanleitung Seite 43

Inhaltsverzeichnis

Werbung

Performance curve VF125
Shimming curve VF125
37.0
15 bar
30.0
25.0
20.0
15.0
10.0
5.0
0
0
5
10
15
0
10
20
30
Displacement 33.3 l/revolution, Capacity is speed x 2.0 in m
Minimum starting torque required: 7000 Nm
Maximum peak power +27%
16
14
7 shims
12
6 shims
10
5 shims
8
4 shims
6
3 shims
4
2
0
0
5
10
15
0
10
20
30
For product temperatures above 65
C and/or viscosity's above 2000 mPa·s use one shim less then shown
o
10 bar
7.5 bar
5 bar
0 bar
20
25
30
35
40
50
60
70
3
/hr
2 shims
20
25
30
35
40
50
60
70
continuous use
intermittent use
max.1 hour running
min. 1 hour stopped
40/60
50/70
60/80
70/90
80/100
40
45
Pump speed (rpm)
80
90
Flow rate (
/hr)
m
3
continuous use
intermittent use
max.1 hour running
min. 1 hour stopped
Pump speed (rpm)
40
45
80
90
Flow rate (
/hr)
m
3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis