Use the device only for the purpose of its determination and pay
particular attention to warning notices on the device and information
on the maximum input values.
Electric safety:
Voltages over 25 VAC or 60 VDC are generally considered
dangerous voltages.
Only work on dangerous voltages by or under the supervision of
qualified personnel.
When working on dangerous voltages, wear suitable protective
equipment and observe the relevant safety rules.
Do not exceed the maximum permissible input values under any
circumstances (risk of serious injury and / or destruction of the
device)
Pay special attention to the correct connection of the test leads
depending on the measuring function in order to avoid a short
circuit in the device. Never apply a voltage in parallel to the current
sockets (A, mA, µA).
Current measurements are always carried out in series with the
consumer, i.e. with the supply line disconnected.
Remove the test probes from the measurement object before
changing the measuring function.
Never touch the bare test probes during the measurement, only
hold the test leads by the handle behind the finger guard. If
applicable, discharge any capacitors before measuring the circuit to
be measured.
The thermocouple for temperature measurements is made of
conductive material. To avoid electric shock, never connect it with a
live conductor.