Parameter
No.
n084
Jump Frequency 2
n085
Jump Frequency 3
n086
Jump Frequency Range
n087
Cumulative operation time
function selection
n088
Cumulative operation time
n089
DC Injection Braking Current
n090
DC Injection Braking Time at
Stop
n091
DC Injection Braking Time at
Startup
n092
Stall Prevention During
Deceleration
n093
Stall Prevention Level During
Acceleration
n094
Stall Prevention Level During
Running
n095
Frequency Detection Level
n096
Overtorque Detection
Function Selection 1
n097
Overtorque/Undertorque Detec-
tion Function Selection 2
n098
Overtorque Detection Level
n099
Overtorque Detection Time
n100
Hold Output Frequency
Saving Selection
n101
Speed Search Deceleration
Time
n102
Speed Search Operation
Level
n103
Torque Compensation Gain
n104
Torque Compensation Time
Constant
n105
Torque Compensation Iron
Loss
EN-16
Description
http://www.kontrolkalemi.com/forum/
Factory
Parameter
Setting
No.
0.00Hz
n106
0.00Hz
n107
0.00Hz
n108
0
n109
0H
n110
50%
n111
0.5s
n112
0.0s
n113
0
n114
170%
n115
160%
n116
0.00Hz
n117
0
n118
0
n119
160%
n120
0.1s
n121
0
n122
n123
2.0s
n124
150%
n125
1.0
n126
0.3s
(Note4)
n127
(Note3)
n128
Description
Motor Rated Slip
Motor Line-to-neutral
Resistance
Motor Leakage Inductance
Torque Compensation
Voltage Limiter
Motor No-load Current
Slip Compensation Gain
Slip Compensation Time
Constant
Slip Compensation During
Regenerative Operation
SI-T/V7 BUS Detection Counter
Stall Prevention Above Base
Speed During Run
Acceleration/deceleration Time
during Stall Prevention
Undertorque Detection
Function Selection 1
Undertorque Detection Level
Undertorque Detection Time
Frequency Reference 9
Frequency Reference 10
Frequency Reference 11
Frequency Reference 12
Frequency Reference 13
Frequency Reference 14
Frequency Reference 15
Frequency Reference 16
PID Control Selection
Factory
Setting
(Note3)
(Note3)
(Note3)
150%
(Note3)
0.0s
(Note4)
2.0s
(Note4)
0
2
0
0
0
10%
0.1s
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0